← 論文一覧に戻る

需給両側の炭素割当不足リスクを考慮したCCUS統合再エネ電力系統の分布ロバスト低炭素運用

Distributionally Robust Low Carbon Dispatch of CCUS-Integrated Renewable Power Systems Considering Source-Load Bilateral Carbon-Quota Shortfall Risk (原題)

Xu Deng, Wenhu Tang, Zeyu Zhang, Xianfu Gong

Sustainability📚 査読済 / ジャーナル2026-11-14#CCUSOrigin: CN経営インパクト: 調達リスク対象セクター: power
DOI: 10.3390/su182211614
原典: https://doi.org/10.3390/su182211614

🤖 gxceed AI 要約

日本語

再エネとCCUSを統合した電力系統において、風力予測誤差が炭素捕捉調整や再給電を引き起こし、発電側・需要側の実現炭素責任が事前割当を超過するリスクを扱う。炭素排出フローで残余排出を需要家へ帰属させ、Sinkhorn距離の曖昧集合と分布ロバスト機会制約で炭素割当不足リスクを制御する運用枠組みを提案。IEEE24母線系統で経済性・削減・炭素リスクの均衡を示した。

English

This paper proposes a distributionally robust low-carbon dispatch framework for CCUS-integrated renewable power systems that explicitly addresses source-load bilateral carbon-quota shortfall risk. Carbon emission flow traces residual emissions to loads, while a Sinkhorn-distance ambiguity set and robust chance constraints manage wind uncertainty and carbon-risk control. Case studies on a modified IEEE 24-bus system show balanced economic, emission, and carbon-risk outcomes.

Unofficial AI-generated summary based on the public title and abstract. Not an official translation.

📝 gxceed 編集解説 — Why this matters

日本のGX文脈において

炭素排出フローによる発電・需要両側への炭素責任配分は、Scope 2・Scope 3の電力由来排出帰属や電力市場での炭素価格付けを検討する日本企業・政策担当者に示唆を与える。

In the global GX context

The source-load carbon responsibility allocation via carbon emission flow connects to global debates on electricity-attributed Scope 2/3 accounting and carbon-informed dispatch under ISSB/CSRD disclosure regimes.

👥 読者別の含意

🔬研究者:不確実性下での炭素責任配分とロバスト最適化を組み合わせた系統運用研究の手法として参考になる。

🏢実務担当者:電力由来排出の需要側帰属と炭素割当リスク管理をScope 2/3算定や調達戦略にどう反映するか示唆を得られる。

🏛政策担当者:電力市場における炭素割当制度設計と需給両側の責任分担ルール検討の参考になる。

📄 Abstract(原文)

Integrating renewable generation with carbon capture, utilization, and storage (CCUS) can facilitate power-sector decarbonization but also introduces coupled operational and carbon-quota shortfall risks under renewable uncertainty. Wind-power forecast errors induce generator redispatch and adjustments in carbon capture, thereby reshaping network power and carbon flows. Consequently, the realized carbon responsibilities of generators and loads may exceed the quotas allocated before uncertainty is realized. To address this issue, this paper proposes a distributionally robust low-carbon dispatch framework that explicitly accounts for source-load bilateral carbon-quota shortfall risk. Carbon emission flow is employed to trace residual generator emissions to individual loads, after which carbon responsibility is allocated between the source and load sides. A Sinkhorn-distance-based ambiguity set and distributionally robust chance constraints are adopted to characterize wind-power uncertainty and control carbon-quota shortfall risk, respectively. A tractable solution method is further developed for the resulting optimization problem. Case studies on a modified IEEE 24-bus system demonstrate the effectiveness of the proposed framework in balancing economic performance, emission reduction, and carbon-risk control.

🔗 Provenance — このレコードを発見したソース

🔔 こうした論文の新着を逃したくない方は キーワードアラート に登録(無料・3キーワードまで)。

gxceed は公開メタデータに基づく研究支援データセットです。要約・翻訳・解説は AI 支援で生成されています。 最終的な解釈・検証は利用者が原典資料に基づいて行うことを前提とします。