本研究は、高さ1〜4mの片持ち式コンクリート擁壁(CCRW)とコンクリート鋼矢板壁(CSP)について、クレードル・トゥ・サイト(A1〜A5)範囲のエンボディドカーボンを比較した。両者とも壁高の増加に伴い総排出量は増えるが、CSPは低高さで20〜30%、4mでは約90%多く排出する。材料生産(A1〜A3)が総排出の85%以上を占め、CSPでは輸送(A4)も大きな負担となる。設計初期段階での炭素考慮と材料・サプライチェーン最適化の重要性を示す。
English
This study compares cradle-to-site (A1–A5) embodied carbon of cantilever concrete retaining walls (CCRW) and concrete sheet piles (CSP) from 1 to 4 m height. Emissions rise with height for both, but CSP emits 20–30% more at low heights and nearly 90% more at 4 m, driven by production and heavier transport. Material production accounts for over 85% of totals, highlighting early-design carbon consideration and material/supply-chain optimization.
Unofficial AI-generated summary based on the public title and abstract. Not an official translation.
📝 gxceed 編集解説 — Why this matters
日本のGX文脈において
建設業のScope 3上流(資材調達)排出や有報・統合報告書でのカーボン開示に関わる実務者にとって、擁壁という見落とされがちな構造物の排出ホットスポット把握に資する。SSBJのScope 3算定や建設業の脱炭素設計に間接的に貢献。
In the global GX context
Adds granular embodied-carbon evidence for an overlooked infrastructure category, supporting Scope 3 upstream accounting and low-carbon design under frameworks like BS EN 15978 and emerging ISSB/CSRD building-disclosure expectations.
👥 読者別の含意
🔬研究者:擁壁システム間のエンボディドカーボン比較手法とホットスポット分析の実証例を提供する。
🏢実務担当者:設計初期段階で擁壁形式・材料・調達先を選ぶ際の炭素削減判断に活用できる。
🏛政策担当者:建設インフラの炭素評価を設計段階で義務付ける際の基礎データとなりうる。
📄 Abstract(原文)
Retaining walls store significant amounts of embodied carbon, yet this aspect is often overlooked due to high material requirements. Although awareness regarding carbon assessment in the built environment sector is growing, comparative studies across different retaining wall systems remain scarce. This study presents a comparative analysis of embodied carbon—within the cradle-to-site scope (Modules A1-A5, BS EN 15978:2011)-for Cantilever Concrete Retaining Walls (CCRW) and Concrete Sheet Piles (CSP), ranging from 1 to 4 m in height. Unlike previous studies that focused on a single system or specific life-cycle stage, this research quantifies emissions arising from material production, transportation, and on-site construction activities. The results indicate that total embodied carbon increases with wall height for both systems. However, CSP consistently generates higher emissions-ranging from 20%-30% higher at lower heights to nearly 90% higher at a height of 4 meters—primarily due to production emissions and a heavier transportation burden. A proportional analysis reveals that material production (A1–A3) accounts for over 85% of total emissions in both systems, whereas transportation (A4) represents a significant additional burden for CSP. This study also identifies emission hotspots and opportunities for carbon reduction for each system. The findings highlight the importance of incorporating embodied carbon considerations into the early design stages and emphasise the need for material optimisation for CCRW and supply chain optimisation for CSP to achieve retaining wall solutions with lower carbon footprints.